Underwriters Laboratories Inc.®
Classified: Foamed Plastic
Control No. 85TO
SURFACE BURNING CHARACTERISTICS
Type M-77 / M-87
1 in. | 2 in. | 4 in. | 5 in. | |
Max. + | Max. + | Max. + | Max. + | |
Flame Spread | 5# | 5## | 5### | 5### |
Smoke Developed | 55-90# | 55-90## | 55-90### | 55-175### |
+ Installed in a thickness, or stored in an effective thickness, as indicated, for a density of 1.00 lb/ft³
# Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 10 and smoke developed index of 200.
## Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 40 and smoke developed index of 450.
### Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 80 and smoke developed index of 450 – over 500.
+ Thickness: 1″, 2″, 4″, 5″
Underwriters Laboratories Inc.®
Classified: Foamed Plastic
Control No. 85TO
SURFACE BURNING CHARACTERISTICS
Type M-77
1 in. | 3 in. | 4 in. | 5 in. | |
Max. + | Max. + | Max. + | Max. + | |
Flame Spread | 5# | 5## | 5### | 5#### |
Smoke Developed | 20# | 40-65## | 40-65### | 40-180#### |
+ Installed in a thickness, or stored in an effective thickness, as indicated, for a density of 1.50 lb/ft³
# Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 25 and smoke developed index of 450.
## Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 75 and smoke developed index of 450 – over 500.
### Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 90 and smoke developed index of over 500.
####Flame spread and smoke developed recorded while material remained in the original test position. Ignition of molten residue on the furnace floor resulted in flame travel equivalent to calculated flame spread index of 95 and smoke developed index of over 500.
+ Thickness: 1″, 3″, 4″, 5″